Research/Experimental Use High Performance Type LC-850K, KS, KD

Features

The LC-850 series of high-functionality zirconia oxygen analyzers was designed based on Toray Engineering's long track record with oxygen analyzers, and enables measurement ranging from ultra-low concentrations to 100% oxygen concentration with a single device.
This series is equipped with our unique zirconia sensor to enable stable and highly accurate measurement over the long term. It can be used in virtually any application, from research to built-in operation in online equipment.

Main Specifications

Type Portable or panel-mounted
Display system Digital
Measurement range 0-1000 ppb / 10 / 100 / 1000 ppm / 1 / 10 / 100 vol%O2 (0-1000 ppb range is not guaranteed)
Response speed Within 90 sec (90 % response)
Repeatability ±1%(at or 1Vol%)
±2% or 0.05ppm whichever is lager (below1vol%)
Sampling system Continuous suction (Built-in sampling pump)
Sample gas rate 200 ±50 mL/min
Sample gas conditions Pressure: Pressurized to at most 0.03 MPa (0.3 kg/cm²)
Humidity: Dew point lower than ambient temperature
Inert gas: Must not contain flammable components, halogen or silica compounds, water droplets, or corrosive components.
Recorder output Output signal: DC 0-10 V, insulation/load resistance 500 Ω max.
DC 4-20 mA, insulation/load resistance 600 Ω max.
Range marker: BCD, 3 contact outputs (Contact capacity: DC 24 V, 0.2 A)
Communication function RS-232C compliant
Alarm output Concentration alarm output
Equipment error alarm output
Automatic calibration function Yes
Automatic refresh function Yes
Ambient temperature 0-40 °C
Warmup time Approx. 20 min
Dimensions 288(W) × 144(H) × 425(D) mm
Weight Approx. 10 kg
Panel cut dimensions 288(W) × 144(H)
Gas connection Gas inlet: Rc1/8
Gas outlet: Rc1/4
Bypass outlet: Rc1/8
Power supply AC 100 V 50/60 Hz
Max. power consumption 200 VA
Standard compliance UL3101-1/CSA No.1010.1

Specifications are subject to change due to product improvements.

LC-850 Communication Functions

LC-850 models are equipped with communication functions to suit the application. Using an RS-232C cable, it is possible perform data management and control the equipment through linkage with a PC.

LC-850 Communication Functions

Please inquire with the sales supervisor for detailed information on each function.

Research/Experimental Use High Performance Type  LC-850K, KS, KD
Oxygen Analyzers
High/Medium Concentration Measurement Type LC-750H
Clean Gas Sampling Equipment Built-in Type LC-750H/PC-110
Dirty Gas Sampling Equipment Built-in Type LC-750H/PC-111
Medium/Low Concentration Measurement Type LC-750L
Clean Gas Sampling Equipment Built-in Type LC-750L/PC-120
Research/Experimental Use High Performance Type LC-850K, KS, KD
Research/Experimental Use High Performance Type LC-860
General-Purpose Type LC-300
Low Concentration Measurement General-Purpose Type LC-450D
Low Concentration Measurement General-Purpose Type LC-450A
Baking and N2 Reflow Use Analyzer RF-30
Baking and N2 Reflow Use RF-400
Separate Sensor Type vacuum deposition SW/LD-300
SD/LD-450
Oxygen Analyzer for Food Packaging LC-450F
Gas Flush Packaging Sampling Inspection Type LC-750F
Oxygen Analyzer for Built-in Packing Machine LF-200
Combustion Management Application Type SE-740/SE-740D
Relevant web pages
Principle of Measurement of Zirconia Oxygen Analyzers
Inquiry
Please use this form to request information or make an inquiry regarding Research/Experimental Use High Performance Type LC-850K, KS, KD.
To an inquiry form
TOP > Measurement & Control Technologies > Oxygen Analyzers